Single-line diagram editor
Model grids, generators, transformers, busbars, lines, cables, motors, loads and switching devices across voltage levels. Enter study inputs alongside each component.
ONLINE SOFTWARE + ENGINEERING SERVICES
Draw the network. Study its behavior. ZeroRiskk SLD Studio brings online load flow, short-circuit analysis and relay coordination into one engineering workspace.
Use the software yourself, or ask ZeroRiskk to perform a scoped engineering study.
Illustrative workflow · not a calculated study result
ONE NETWORK MODEL
Power system analysis examines how a network operates in normal and fault conditions. SLD Studio connects the electrical diagram, equipment data and study cases so you can review the network in context.
Model grids, generators, transformers, busbars, lines, cables, motors, loads and switching devices across voltage levels. Enter study inputs alongside each component.
Review bus voltage, angle, active and reactive power, branch current, losses and equipment loading. Compare operating cases and identify voltage or loading concerns.
Study fault currents at selected locations, examine source contributions, and review current through interrupting devices against the supplied equipment data.
Review time-current relationships and grading for the modeled protection devices. Examine proposed settings and operating sequences with the project’s protection requirements in mind.
Change service states and study cases to examine different network conditions. Check topology and missing parameters before interpreting results.
Keep the diagram, input schedules and study outputs available for review. Export supported drawing and report formats from the workspace.
PREPARE A USEFUL MODEL
Start with an up-to-date single-line diagram and the operating case you want to investigate. Required data varies with the study and equipment type.
Voltage levels, frequency, connectivity, grid fault data and generator information.
Transformer ratings, impedance and grounding; cable or line data; motor and load information.
Device ratings, CT/VT data, relay settings, normal and contingency operating arrangements.
ENGINEERING SERVICES
ZeroRiskk provides power system analysis services for teams that need an engineering study or an additional review. Send your study objective, network scope and available data so we can discuss the work required.
Request a power system study ↗Scope, deliverables, data requirements, fees and schedule are discussed for each project.
A WORKED PRACTICE NETWORK
The 16-chapter tutorial follows a training network through model preparation, operating studies, fault studies, coordination and exports. The model uses provisional training inputs.

Download the practice SLD and review equipment schedules in the worksheet.
Open SLD Studio and use the tutorial button to follow the chapter relevant to your task.
Compare cases and use the worksheet’s practice checks. Replace provisional values before applying a model to a real project.
BEFORE YOU BEGIN
Yes. SLD Studio provides a browser-based drawing and study workspace. Open the tool to create a network, supply equipment parameters and review the available study options. Account and payment requirements are shown in the workspace.
Load flow studies the operating condition of a network, including voltages, power flows and loading. Short-circuit analysis examines fault currents for a selected fault and network condition. They answer different engineering questions using related model data.
Yes. Contact us with your study objective, single-line diagram, voltage levels and available equipment data. We can discuss a study scope and the information needed to prepare a proposal.
Check the study scope, equipment inputs, operating case and method assumptions. The tutorial and worksheet provide a reproducible training example, not independent validation of every network or protection scheme. Final design and settings decisions require qualified engineering review.
For a recorded event, use COMTRADE file analysis to inspect waveforms and digital timing. A network model and a disturbance record provide complementary evidence.